124
16.2.2. Erase all programs in the controller
To delete all programs, follow the procedure below.
(1) Tap the [Initialize] button<a> of “program”.
(2) Tap the [Edit] button<b> of the confirmation screen.
(3) Input "YES" with the keyboard, and tap the [Enter] key.
(4) Tap the [OK] button<c> of the confirmation screen.
All programs in the robot controller are deleted by operating the above-mentioned.
16.2.3. Initialize the battery remaining time
To initialize the battery remaining time, follow the procedure below. This function can not be used when
connected to the CR800 series robot controller.
(1) Tap the [Initialize] button of “battery remaining time".
(2) Tap the [Edit] button<b> of the confirmation screen.
(3) Input "YES" with the keyboard, and tap the [Enter] key.
(4) Tap the [OK] button<c> of the confirmation screen.
The battery remaining time is initialized by operating the above-mentioned.
<a>
<c>
<b>