EasyManua.ls Logo

Mitsubishi Electric R56TB - User Definition Parameter

Mitsubishi Electric R56TB
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
186
17.4.29. User definition parameter
In the “User definition parameter” window, it is possible to edit the parameters, which prepared by the definition
files, at the one window.
Create the definition files beforehand in PC, and copy the files to T/B.
File name
Paramxx.TXT (xx = 01 to 10)
It is possible to create the different definition files up to 10.
Folder in T/B to copy to
/ IPSM / MELFA / UserDef
Please make the “UserDef” folder by yourself.
Format of the parameter definition
The 1st line : “;” (semicolon) + title string
The 2nd line : parameter name + “;” (semicolon)
One parameter name is written on one line, and these can be arrayed up to 10 line.
(Example)
;Ethernet parameter
NETIP;
NETMSK;
NE TPORT;
CPRCE11;
COMDEV;
NETMODE;
NETHSTIP;
MXTCOM1;
MXTTOUT;

Table of Contents