CIRCUIT DIAGRAMS
-
Power Window Circuit
221
OPERATION
l Turn on the ignition switch, and the transistor Tr will be turned on by the timer circuit. This will turn
on the power window relay allowing the power window to be opened and closed.
l Turn the ignition switch from on to off, and the timer circuit will be activated to keep transistor Tr
on for 30 seconds allowing the power window to be opened and closed.
Moreover, if the front door is opened, the timer circuit will stop to turn off the transistor Tr. This
will prevent the window from being opened and closed.
TROUBLESHOOTING HINTS
’
Phenomenon
Inspection method
All door windows cannot be opened or closed.
e
Check fusible link No. 9.
0
Check the power-window relay.
l
Check the power-window main switch.
One of the door windows
Neither of the power- l
Check the power-window main switch.
cannot be opened or
window switches (main
l
closed.
Check the power-window motor for the power window that
or sub) operates
does not operate.
Either the power-win- l
Check the power-window switch for the power window
dow main switch or sub
that does not operate.
switch does not oper-
ate.
The one-touch down switch function only does not
l
Replace the power-window main switch.
operate.
The power windows do not operate when the ignition
l
Check the ignition switch input signal. (Refer to GROUP
switch is at the “ON” position.
42-Troubleshooting.)
0
Check the ignition switch. (Refer to GROUP
54-Ignition
Switch.)
l
Checkthepowerwindow relay. (RefertoGROUP42-Power
Window)
The power windows can be opened and closed l
Check the front door switch input signal. (Refer to GROUP
immediately after ignition switch is switched “OFF”,
42-Troubleshooting.)
but the power window operation does not stop if a
l
front door is opened within 30 seconds.
Check the front door switch. (Refer to GROUP 42-Door
Assembly.)
The opening and closing operations of the power l
Check the power window relay. (Refer to GROUP 42-Power
windows are possible after the timer operation time
Window.)
has elapsed when the ignition switch is set to the
“OFF” position.
/
i
TSB Revision