GENERAL
-
Harness Connector Inspection
25
~
Z16R1320
(2)
Insert harness of terminal to be rectified deep into connec-
tor from harness side and hold it there.
Housing lance
/
’
Needle
’
Housing lance
Z16R132
(3)
Insert tip of screwdriver
[1.4
mm
(.06
in.) width] into connec-
tor in a manner as shown in the figure, raise housing
lance slightly with it and pull out harness.
Caution
Tool No. 753787-l supplied by AMP can be used
instead of screwdriver.
(4)
insert
needle through a hole provided on terminal and
raise contact point of male terminal.
ROUND WATERPROOF CONNECTOR
(1) Remove waterproof cap by using a screwdriver.
(2) Insert tip of screwdriver
[I.4
mm
(.06
in.) or 2.0 mm
(.08
in.) width] into connector in a manner as shown in the
figure, raise housing lance slightly with it and pull out
harness.
(3) Insert screwdriver through a hole provided on terminal
and raise contact point of male terminal.
1
TSB Revision