16-14
ENGINE ELECTRICAL
-
Charging System
(From 1996 models)
Disassembly steps
+A,
,A+
::
~%?
assembly
3.
Rear bearing
4.
Bearing retainer
5.
Front bearing
6.
Front bracket
45,
7.
Stator
assembly
13
TEN0906
8. Plate
9. Regulator and brush holder
10. Brush
11. Slinger
12. Rectifier assembly
13. Rear bracket
I
DISASSEMBLY SERVICE POINT
dAbGENERATOR
PULLEY REMOVAL
(1) Remove the bolts.
(2) Insert plain screwdriver between front bracket and
stator
core and pry downward.
Caution
Do not insert screwdriver too deep, as there is
danger of damage to
stator
coil.