26
GENERAL
-
Harness Connector Inspection
Front holder
\\Z16R1325]
Housing lance
7,fiEL,
c
Terminal lance
00000400
\
RECTANGULAR WATERPROOF CONNECTOR
(1)
Disengage front holder by using a screwdriver and remove
it.
(2) Inset-t tip of screwdriver
[*0.8
mm
(.03
in.) width] into con-
nector in a manner as shown in the figure, push it lightly
to raise housing lance and pull out harness.
*If right size screwdriver is not available, convert a conven-
tional driver to suit the size.
(3) Press contact point of male terminal down by holding a
screwdriver
[1.4
mm
(.06
in.) width] in a manner as shown
in the figure.
INJECTOR CONNECTOR
(1) Remove waterproof cap.
(2)
Insert tip of screwdriver
[1.4
mm
(.06
in.) width] into connec-
tor in a manner as shown in the figure, press in terminal
lance and pull out harness.
(3) Press contact point of male terminal down by holding a
screwdriver
[1.4
mm
(.06
in.) width] in a manner as shown
in the figure.
Caution
Make sure that lance is in proper condition before
terminal is inserted into connector.
1