54-34
CHASSIS ELECTRICAL
-
Meters and Gauges
216FO14C
216FO14:
216FO141
INSPECTION
PRESSURE GAUGE CHECK <Turbo>
Measure resistance between terminals with circuit tester.
Standard value: Approx. 72
&2
VOLTAGE GAUGE CHECK <Non-Turbo>
Refer to
P.54-30
OIL PRESSURE GAUGE CHECK
Measure resistance between terminals with circuit tester.
Standard value: Approx. 42
Q
ENGINE COOLANT TEMPERATURE GAUGE CHECK
(1) Remove the
IG
terminal
scre\;/
from area A.
(2) Measure resistance between terminals with circuit tester.
Caution
For inspection, use a circuit tester which uses a mea-
surement current of 4
mA
or less.
Standard value:
A-B
Approx. 51
Sz
A-C
Approx. 139
Q
B-C
Approx. 190
R
1
TSB Revision