172
Data Code
Func-
tion
Parameter
Number
Name
Read Write
Link Parameter Extension
Setting
(Data Code 7F/FF)
57
Restart coasting time
39 B9 0
Automatic
restart
functions
58
Restart cushion time
3A BA 0
60
Shortest acceleration/deceleration
mode
3C BC 0
61
Reference I for intelligent mode
3D BD 0
62
Reference I for intelligent mode
acceleration
3E BE 0
63
Reference I for intelligent mode
deceleration
3F BF 0
65
Retry selection
41 C1 0
66
Stall prevention operation level
reduction starting frequency
42 C2 0
67
Number of retries at alarm
occurrence
43 C3 0
68
Retry waiting time
44 C4 0
69
Retry count display erasure
45 C5 0
70
Special regenerative brake duty
46 C6 0
71
Applied motor
47 C7 0
72
PWM frequency selection
48 C8 0
75
Reset selection/disconnected PU
detection/PU stop selection
4B CB 0
77
Parameter write disable selection
4D CD 0
78
Reverse rotation prevention
selection
4E CE 0
Operation selection functions
79
Operation mode selection
4F CF 0
80
Motor capacity
50 D0 0
82
Motor exciting current
52 D2 0
83
Rated motor voltage
53 D3 0
84
Rated motor frequency
54 D4 0
90
Motor constant (R1)
5A DA 0
General-purpose
magnetic flux
vector control
96
Auto-tuning setting/status
60 E0 0
117 Station number 11 91 1
118 Communication speed 12 92 1
119 Stop bit length 13 93 1
120 Parity check presence/absence 14 94 1
121 Number of communication retries 15 95 1
122
Communication check time
interval
16 96 1
123 Waiting time setting 17 97 1
Communication
functions
124
CR
LF presence/absence
selection
18 98 1
145
Parameter unit language switch
over
2D AD 1
Additional
function
146
Parameter set by manufacturer. Do not set.
150 Output current detection level 32 B2 1
151 Output current detection period 33 B3 1
152 Zero current detection level 34 B4 1
Current
detection
153 Zero current detection period 35 B5 1
Sub
function
156
Stall prevention operation
selection
38 B8 1

Table of Contents