29 Data Table Operation – FNC250 to FNC269
29.6 FNC261 – BINDA / BIN to Decimal ASCII Conversion
b) "20H (space)" is stored for "0" on the left side of the effective digits (zero suppression).
c) +3 is set as follows depending on the ON/OFF status of M8091.
2. 32-bit operation (DBINDA and DBINDAP)
1) Each digit of 32-bit binary data stored in [ +1, ] is converted into an ASCII code (30H to 39H), and
stored in and later.
For example, when [ +1, ] stores "-12,345,678", the conversion result is stored in and later as
follows:
2) The numeric range of 32-bit binary data stored in [ +1, ] is from -2,147,483,648 to +2,147,483,647.
3) The conversion result stored in is as follows:
a) "sign data" (low-order byte of ) "20H (space)" is set when the 32-bit binary data stored in [ +1,
] is positive, and "2DH (-)" is set when 32-bit binary data stored in [ +1, ] is negative.
b) "20H (space)" is stored for "0" on the left side of the effective digits (zero suppression).
c) The high-order byte of +5 is set as follows depending on the ON/OFF status of M8091.
ON/OFF status Contents of processing
M8091=OFF
+3 is set to "0000H (NULL)".
M8091=ON
+3 does not change.
ON/OFF status Contents of processing
M8091=OFF
The high-order byte of +5 is set to "00H (NULL)."
M8091=ON
The high-order byte of +5 is set to "20H (space)."
0 0 3 2 5
20H
Effective digits
D
D
D
S
S
D
Command
input
FNC261
DBINDAP
S
D
+0
b15
+2
b8 b7 b0
D
+1
High-order 16 bits
32-bit binary data
+3
+5
+4
Low-order 16 bits
S
+1 S
M8091=OFF:00H
M8091=ON:20H
ASCII code for 100,000's digit
ASCII code for 1,000,000's digit
ASCII code for 1,000,000,000's digit
ASCII code for 10,000,000's digit
Sign data
ASCII code for 100,000,000's digit
00H or 20H ASCII code for 1's digit
ASCII code for 1000's digit
ASCII code for 10's digit
ASCII code for 10000's digit
ASCII code for 100's digit
S
S
D
+0
b15
+2
b8 b7 b0
D
+1
+3
+5
+4
33H(3) 32H(2)
20H (space)
31H(1)
2DH(-)
20H (space)
00H or 20H 38H(8)
35H(5)
37H(7)
34H(4)
36H(6)
M8091=OFF:00H
M8091=ON:20H
S
+1 S
-12345678
S
S
D
D
S
S
S
S
0 0 1 2 0 3 4 5 6 0
20H
Effective digits
D
D
D

Table of Contents

Other manuals for Mitsubishi FX3G Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3G Series and is the answer not in the manual?

Mitsubishi FX3G Series Specifications

General IconGeneral
ModelFX3G Series
Power SupplyAC 100-240V or DC 24V
Program Capacity32, 000 steps
Execution Speed0.21 µs/basic instruction
Communication OptionsRS-422, USB, Ethernet
Expansion ModulesAnalog, digital, communication
Programming LanguageLadder Logic, Instruction List
Built-in FunctionsHigh-speed counters, pulse output
Analog I/OAvailable via expansion modules

Related product manuals