847
FX3G/FX3U/FX3GC/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC276-FNC279
Data
Transfer 3
32
FNC280-FNC289
High-Speed
Processing 2
33
FNC290-FNC299
Extension File
Register
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
FX3U-CF-ADP [ch2] (Refer to CF-ADP Manual for details.)
[D]8420 to [D]8421 Not used –––
[D]8422
Step number of executing CF-ADP instruction
*2
3
*1
3
*1
–––
[D]8423
3
*1
3
*1
–––
[D]8424 to [D]8425 Not used
–––
[D]8426 CF-ADP status
3
*1
3
*1
–––
[D]8427 Not used
–––
[D]8428 CF-ADP version
3
*1
3
*1
–––
[D]8429 to [D]8433 Not used
–––
[D]8434
Error step number of M8438
*2
3
*1
3
*1
–––
[D]8435
3
*1
3
*1
–––
[D]8436 Not used
–––
[D]8437
Error code in detail for CF-ADP instructions
*2*3
3
*1
3
*1
–––
[D]8438
Error code for CF-ADP instructions
*2*3
3
*1
3
*1
–––
[D]8439 Operation mode display
–––
*1. Available in Ver. 2.61 or later.
*2. Cleared when PLC switches from STOP to RUN.
*3. For details on the error code is stored in special data register, refer to the CF-ADP Manual.
Error Detection (Refer to Chapter 38 for details.)
[D]8438
*4
Error code for serial communication error 2 [ch2]
3 3 3 3 M8438
RS2 (FNC 87) [ch2] and Computer Link [ch2] (Refer to Data Communication Edition for details.)
[D]8439 Operation mode display [ch2] 3 3 3 3 –––
Error Detection (Refer to Chapter 38 for details.)
[D]8440 to [D]8448 Not used –––
[D]8449 Special block error code 3 3 3
3
*5
M8449
[D]8450 to [D]8459 Not used
–––
*4. Cleared when PLC power supply is turned from OFF to ON.
*5. Available in Ver. 2.20 or later.
Positioning [FX3G, FX3U, FX3GC and FX3UC PLCs] (Refer to Positioning Control Edition for details.)
[D]8460 to [D]8463 Not used 3 3 –––
D 8464
DSZR (FNC150) and ZRN (FNC156) instructions:
[Y000] Clear signal device specification
3 3 3
3
*6
M8464
D 8465
DSZR (FNC150) and ZRN (FNC156) instructions:
[Y001] Clear signal device specification
3 3 3
3
*6
M8465
D 8466
DSZR (FNC150) and ZRN (FNC156) instructions:
[Y002] Clear signal device specification
3 3
3
*6
M8466
D 8467
DSZR (FNC150) and ZRN (FNC156) instructions:
[Y003] Clear signal device specification
3
*7
M8467
*6. Available in Ver. 2.20 or later.
*7. Available only when two FX3U-2HSY-ADP adapters are connected to an FX3U PLC.
Error Detection
[D]8468 to [D]8488 Not used –––
[D]8489 Error code for special parameter error
3
*9
3
*9
3
*8
3
*8
M8489
[D]8490 to [D]8511 Not used
–––
*8. Available in Ver. 3.10 or later.
*9. Available in Ver. 2.00 or later.
Number and name Content of register
Applicable model
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX
2NC

Table of Contents

Other manuals for Mitsubishi FX3G Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3G Series and is the answer not in the manual?

Mitsubishi FX3G Series Specifications

General IconGeneral
ModelFX3G Series
Power SupplyAC 100-240V or DC 24V
Program Capacity32, 000 steps
Execution Speed0.21 µs/basic instruction
Communication OptionsRS-422, USB, Ethernet
Expansion ModulesAnalog, digital, communication
Programming LanguageLadder Logic, Instruction List
Built-in FunctionsHigh-speed counters, pulse output
Analog I/OAvailable via expansion modules