6 Introduction of Functions
6.2 Basic Functions
46
FX3U-16CCL-M User's Manual
Write to remote register (RWw)
7) The PLC writes the transmission data to the buffer memory "remote register (RWw)" using the TO
instruction.
8) The data stored in the buffer memory "remote register (RWw)" is automatically (for each link scan)
transmitted to the remote register (RWw) in the remote device stations.
Master station
Remote device station
(Station No. 1:
Occupies 2 stations)
RWw 0
RWw 1
RWw 2
RWw 3
RWw 4
RWw 5
RWw 6
RWw 7
RWw 8
RWw 9
RWw 3E
RWw 3F
...
Remote register (RWw)
RWw 0
RWw 1
RWw 0
RWw 1
Remote device station
(Station No. 3:
Occupies 2 stations)
RWw 2
RWw 3
RWw 4
RWw 5
RWw 6
RWw 7
RWw 3D
RWw 2
RWw 3
RWw A
RWw B
RWw C
RWw D
RWw E
RWw F
RWw 10
RWw 11
RWw 12
RWw 13
RWw 3C
Remote register (RWw)
Remote register (RWw)
TO
7)
PLC
8)
8)
RWw 4
RWw 5
RWw 6
RWw 7

Table of Contents

Other manuals for Mitsubishi FX3U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U and is the answer not in the manual?

Mitsubishi FX3U Specifications

General IconGeneral
SeriesFX3U
Program Capacity64k steps
TypePLC
Power SupplyAC: 100-240V, DC: 24V
I/O PointsUp to 384 points
CommunicationRS-232C, USB, Ethernet
ExpansionSupports multiple expansion modules including I/O, analog, and communication modules
Programming LanguageLadder Logic, SFC, Function Block Diagram
High-speed Processing0.065 μs per basic instruction
Analog I/OAvailable with expansion modules
Positioning ControlUp to 3 axes of positioning control
Weight0.3 kg (Main unit)