Service
-
127
-
'10 HM-T-149
Supply water temperature control in heating
Target supply water temperature can be seen in Menu 2.0 (for heating system 1) and 3.0 (for heating system 2).
For dual system, the target temperature for downstream heating system must be lower than that for upstream heating system.
Heating curve
Heating curve is the basic principle to decide the target supply water temperature for heating.
The lower the outdoor air temperature (BT1) becomes, the higher the target supply water temperature becomes, and the characteristics
can be adjusted in Menu 2.1.2 (for heating system1) or in Menu 3.2 (for heating system 2).
The gure below shows the case that heating curve 9 is chosen. In this case, the target supply water temperature is 55°C at -20°C
outdoor air temperature condition.
Heating curve offset 0
30
40
50
60
70
oC
FRAMLEDNINGSTEMPERATUR
- 40 oC
UTETEMPERATUR
- 10
0
10
- 20 - 30
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
V
Ä
RMEKURVA
- 5
+ 5
FÖRSKJUTNING
VÄRMEKURVA (0)
HEATING CURVE
OFFSET HEAT CURVE
Outdoor air temperature
Supply water temperature
Heating curve offset
It is possible to offset the heating curve chosen in the menu above in order to obtain higher target supply water temperature.
The offset for heating system 1 can be set using the knob on the controller. The set value can be seen in Menu 2.1.1.
The gure below shows the case that heating curve 9 is chosen with heating curve offset +2. In this case, the target supply water
temperature is 60°C at -20°C outdoor air temperature condition.
Heating curve offset +2
1514 13 12 11 10
8
7
6
5
4
3
2
1
- 40 oC
UTETEMPERATUR
- 10
0
10
- 5
+ 5
30
40
50
60
70
oC
FRAMLEDNINGSTEMPERATUR
- 20 - 30
FÖRSKJUTNING
VÄRMEKURVA (+2)
9
V
Ä
RMEKURVA
HEATING CURVE
OFFSET HEAT CURVE
Outdoor air temperature
Supply water temperature
The offset for heating system 2 can be set in Menu 3.1.
Operation control function by the indoor unit controller

Table of Contents

Other manuals for Mitsubishi HMA100V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi HMA100V and is the answer not in the manual?

Mitsubishi HMA100V Specifications

General IconGeneral
BrandMitsubishi
ModelHMA100V
CategoryHeat Pump
LanguageEnglish

Related product manuals