Error
display/reset
When an error occurs in AUTO mode of the PGU, the error code can be read if the mode is changed
to the MANUAL mode using the following operation.
I
PGU
Error code number
Display of the error
code number
ERROR
CEXX
'IF
OK-GO
-
If
there is
no error
LIW%
FX-1GM
ERROR CEO
0-
0
Ern7
0CW.E
I
Execution
of
OEZ
error reset
I
c
Repeat after eliminating SELECT MANUiSTOP
the cause of the trouble From any point
When a transmission cable makes connection failure,
a transfer trouble
is
generated.
When the error
is
reset, the
LED
of
the
PGU
is turned OFF and the error detection signal
BFM#3
b6
to
the programmable controller is also turned
OFF.
It
can also be reset by turning
on
the STOP input manually. However, care must be taken in this
case, as the error code is reset and lost. (Error code: see pages
108
to
110.)
Fixed
length
feed
The fixed length feed operation can be executed from the teaching panel. The system unit in this
case is dependent upon the setting value of
PARA
number
3.
Current position FEED 123456709
Correction
-+
Refeed
n
Setting other distance
-
62
-