Page #1130 background image
App-122
Category Instruction Condition (Device)
Processing Time (µs)
L02CPU L26CPU-BT
Min. Max. Min. Max.
Basic
instruction
LDE=
Single
precision
In conductive status 3.900 10.000 0.0285
In non-conductive status 3.900 10.000
0.0285
ANDE=
Single
precision
When not executed 0.120
When
executed
In conductive status 3.400 9.300 0.0285
In non-conductive status 3.400 9.300 0.0285
ORE=
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.500 8.500 0.0285
In non-conductive status 3.500 8.500 0.0285
LDE< >
Single
precision
In conductive status 3.900 10.000 0.0285
In non-conductive status 3.900 10.000 0.0285
ANDE< >
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.400 9.300 0.0285
In non-conductive status 3.400 9.300 0.0285
ORE< >
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.500 8.500 0.0285
In non-conductive status 3.500 8.500 0.0285
LDE>
Single
precision
In conductive status 3.900 10.000 0.0285
In non-conductive status 3.900 10.000 0.0285
ANDE>
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.400 9.300 0.0285
In non-conductive status 3.400 9.300 0.0285
ORE>
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.500 8.500 0.0285
In non-conductive status 3.500 8.500 0.0285
LDE<=
Single
precision
In conductive status 3.900 10.000 0.0285
In non-conductive status 3.900 10.000 0.0285
ANDE<=
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.400 9.300 0.0285
In non-conductive status 3.400 9.300 0.0285
ORE<=
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.500 8.500 0.0285
In non-conductive status 3.500 8.500 0.0285
LDE<
Single
precision
In conductive status 3.900 10.000 0.0285
In non-conductive status 3.900 10.000 0.0285
ANDE<
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.400 9.300 0.0285
In non-conductive status 3.400 9.300 0.0285
ORE<
Single
precision
When not executed 0.120 0.0285
When
executed
In conductive status 3.500 8.500 0.0285
In non-conductive status 3.500 8.500 0.0285

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals