6-124
FMOV(P)
Program Example
(1) The following program outputs the lower 4 bits of D0 when XA goes ON to Y10 to Y23 in
4-bit units.
[Ladder Mode] [List Mode]
[Operation]
(2) The following program outputs the data at X20 through X23 to D100 through D103 when XA
goes ON.
[Ladder Mode] [List Mode]
[Operation]
Step
Instruction
Device
1 Y13 to Y10011
1011
1011
1011
1
0
11
Y17 to Y14
Y1B to Y18
Y1F to Y1C
Y23 to Y20
1011 10110 111 1001D0
Transfer
Ignored
b0b3b15 b4 b2 b1
5 points
Step
Instruction
Device
0
111
111
0
1 1
0
1
X20X23X2B X28X2F X2C
00
1
0
X27 X24
0000 11100 000 0000
Before execution
D100
After execution (destination of transfer)
0000 11100 000 0000 D101
0000 11100 000 0000 D102
0000 11100 000 0000 D103
4 points
Filled with 0s.
b0b3b15 b4
Ignored