6-146
RFS(P)
Operation Error
(1) In the following case, an operation error occurs, the error flag (SM0) turns ON, and an error
code is stored into SD0.
• The range n points from the device designated by exceeds the proximate I/O range.
(Error code: 4101)
Program Example
(1) The following program refreshes X100 to X11F and Y200 to Y23F when M0 goes ON.
[Ladder Mode] [List Mode]
S
Step
Instruction
Device