5. Remove the compressor wires, compressor cover,
and the right.
Compressor cover
(top)
4. Remove the compressor cover (top).
Compressor cover
(right)
Protection for the
sealing material
Suction piping
Protection for the
compressor cover
6. Place protective materials on the insulation lining of
the compressor cover and on the sealing material
on the compressor suction pipe to protect them from
the torch flame, debraze the pipe, and replace the