Check PA Stages
No power or low power when keyed
Measure DC Voltage at Pin 2 & 3 of U4401
>6
YES
DC Voltage
at U4501
Pin 23 =0?
2-6
DC Voltage
at U4402-1
Pin 1?
YES
Pin 2
Voltage 0.62
* Voltage at
Pin 1?
If U4201 Pin 2 is high,
replace PCIC
NO
Replace U4401
YES
NO
DC
Voltage at
U4402-1 Pin
3 = 8.8V?
Check S4440,
R4442 and R4443
YES
Pin 3
Voltage 0.51
* Voltage at
Pin 1?
NO
Replace U4401
<2V
DC
Voltage at
U4402-2
Pin 7?
>6V
Check Components
between U4402-2 Pin 7
and Q4421. Check
Resistive Network at
Pins 5 & 6 before
replacing Q4421
YES
DC
Voltage at
U4402-2 Pin 5
<8.8V?
Check Components
between U4402-2 Pin 7
and Q4421. Check Resis-
tive Network at Pins 5 & 6
before replacing Q4421
NO
Check Q4422
NO
Check Final PA Stage
2-6V
<2V
Check Resistive
Network at Pins 2 & 3
of U4402-1 before
replacing U4401
Check Q4442 and
Resistive Network at
U4402-1 Pin 3
before replacing
U4401

Table of Contents

Other manuals for Motorola Pro3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola Pro3100 and is the answer not in the manual?

Motorola Pro3100 Specifications

General IconGeneral
BrandMotorola
ModelPro3100
CategoryTwo-Way Radio
LanguageEnglish

Related product manuals