Do you have a question about the Moxa Technologies ioLogik E1214 and is the answer not in the manual?
Digital Inputs | 8 |
---|---|
Digital Outputs | 4 |
Communication Interface | Ethernet |
Power Supply | 12 to 48 VDC |
Operating Temperature | -10 to 60°C (14 to 140°F) |
Mounting | DIN-Rail |
Digital Input Type | Dry Contact |
Protocols | Modbus TCP, SNMP |
Storage Temperature | -40 to 85 °C |
Certifications | CE, UL |
Humidity | 5 to 95% RH |
Covers the physical installation procedures for the ioLogik E1200 unit.
Explains how to mount the unit using DIN-Rail or wall mounting methods.
Instructions for properly grounding the ioLogik E1200 unit for safety and stability.
Guides on setting jumpers for different I/O channel configurations.
Provides wiring instructions for various types of I/O channels.
Details on how to correctly wire the Ethernet communication ports.
Steps and precautions for powering on the ioLogik E1200.
Configuration of network parameters like IP address, subnet mask, and gateway.
Basic settings for server name, location, and communication watchdog.
Setup for static or dynamic IP addressing and network parameters.
Allows custom configuration of Modbus/TCP addresses for I/O points.
Configuration for all types of I/O channels: DI, DO, AI, AO, RTD, TC.
Configuration settings for Digital Input channels, including event counting.
Configuration settings for Digital Output channels, including pulse output.
Configuration settings for Analog Input channels, including modes and ranges.
Setting the input ranges for Analog Input channels (Voltage or Current).
Configuration settings for Analog Output channels, including modes and scaling.
Configuration settings for Resistance Temperature Detector channels.
Configuration settings for Thermocouple channels, including calibration.
Enabling and configuring the EtherNet/IP communication protocol.
Tools for managing the device, including firmware updates and settings.
Procedure for loading new firmware onto the ioLogik E1200.
Core operational functions available through ioSearch.
Process for remotely upgrading the firmware of ioLogik devices.
Efficiently upgrading firmware on multiple devices simultaneously.
Modifying the IP address of one or multiple ioLogik devices.
Simultaneously configuring TCP/IP settings for multiple devices.
Steps to install EDS files for the ioLogik E1200 in RSLogix 5000 software.
Procedure for setting up communication between ioLogik E1200 and Allen-Bradley PLC.
Steps to enable and configure the RESTful API for applications.