Trigger Box Quick Start Guide
20
Flair is not receiving a
Sync signal from the
Trigger Box.
Make sure the CAM TEST ON/OFF switch is in
the correct position (page 13). The switch must
be Off if you want Flair to receive the signal
from a real camera that is connected to the
EXT. SYNC connectors on the Trigger Box, and
On if you want Flair to receive the signal from
the simulated camera (Sync signal generator)
in the Trigger Box.
If you testing Flair with the simulated camera
(Sync signal generator), make sure the INT
CAM CONTROL ON/OFF switch is in the
correct position (page 13). If the switch is Off
then the internal simulated camera (Sync
generator) is under Flair control, and you will
need to activate the Sync signal by activating
the External Camera from Flair (Setups >
Outputs > Test O u tputs, page 15).
Symptoms Cause and/or action