EasyManua.ls Logo

MS Topcoater - Overview Front Corona Modus in Nm3; Pneumatic Settings

MS Topcoater
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PNEUMATIC SETTINGS
OVERVIEW FRONT CORONA
MODUS IN Nm3
This setting is called when the unit is set to Nm3 / h.
Theunitcanbesetinthecongurationmenuonpage
1. See section 4.7.1 on page 37.
Setting the Feed Air
The feed air is used to adjust the amount of powder. The
more feed air is set, the more powder output is achieved.
Standard Setting 50%.
Setting the Dosage Air
The dosage air is used for setting the kinetic propulsion of
the powder cloud. Standard Setting 3.6Nm3/h4.
Setting the Gun Air
The gun air is used to cool the electrode and for ventilation
ofthebafeplate.StandardSetting0.0Nm3/h.
0
1
2
3
4
5
6
0
10
20
30
60
70
100
40
50
80
90
0
10
20
30
60
70
100
40
50
80
90
Nm
3
/h
4
kV
µA
PROGRAMS
CLEANING
ONE LAYER
TWO LAYER
OFF ON
bar
+
+
+
GUN PANEL topcoat PRG: 1 STANDARD 12/10/2015 13:11:53
3.6
70 10
0.0
0
10
20
30
60
70
100
40
50
80
90
+
50
%
0
10
20
30
60
70
100
40
50
80
90
+
50
%
0
1
2
3
4
5
6
Nm
3
/h
4
+
3.6
Nm
3
/h
0.0
PA-18-02-R0 (08/2018) 28 / 52 www.carlisleft.com
EN
MAINTENAMCE

Table of Contents