ASSIGNMENT OF KEYS
Bottom menu programs
Switch to the Programs
Bottom cleaning
Start cleaning up for press again
Standard program
The default is two standard programs.
• Program Standard surface part (ONE LAYER)
• Program secondary coating (TWO LAYER)
Bottom On Off
Setting the high voltage
With this, the high voltage of the gun can be adjusted.
Depending on the powder charging is set between 40 kV
to80kV.Standardpowdercanbesetwithapproximately
70 kV Metallic powders are set about 50 - 60 kV.
Setting the current control
Thecurrentregulationhasagreatinuenceonthechargeon
thepowder.Asarule,littleelectricityisused.Approximately
20 µA. In weakly chargeable powder, the amount of current
must set higher. In case of over coating or MDF coating, the
amountofcurrentcanbesetlow.Approximately8-10µA.
ELECTRICAL SETTINGS
NOTE
Incaseofexcessiveamountofelectricity
produced orange peel.
0
10
20
30
60
70
100
40
50
80
90
kV
+
–
70
0
10
20
30
60
70
100
40
50
80
90
µA
+
–
10
PROGRAMS
CLEANING
ONE LAYER
TWO LAYER
OFF ON
PA-18-02-R0 (08/2018) 29 / 52 www.carlisleft.com
EN
MAINTENAMCE