MTS 793 Controller Hardware
208
Model 493.42 System I/O Connections
The Model 493.42 System I/O module is a dual-wide VME-based slave
board used in the Model 493.02 chassis.
Provides box-in and box-out, analog and digital I/O, E-Stop, and
HSM and HPU control.
Contains three general purpose digital input channels and three
general purpose digital output channels.
Interfaces the controller with a hydraulic power unit.
Interfaces the controller with a hydraulic service manifold and
other devices.
Provides one BNC channel for analog output signals. The output
signals are within ±10 V DC.
Provides one BNC channel of analog input. The input signals must
be within ±10 V DC.
J25 Hydraulic Power Unit Connection
Connector J25 HPU controls the hydraulic power unit (HPU).
The connector provides 24 V logic signals to control the HPU.
The connector may be connected directly to MTS Series 505 HPUs,
other MTS HPUs via the Model 493.07 HPU Converter Box, and
24 V PLC compliant HPUs.
Note See “Hydraulic Configurations” on page 221 for more information.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems FlexTest IIm and is the answer not in the manual?

MTS Systems FlexTest IIm Specifications

General IconGeneral
BrandMTS Systems
ModelFlexTest IIm
CategoryController
LanguageEnglish

Related product manuals