MTS 793 Controller Hardware
208
Model 493.42 System I/O Connections
The Model 493.42 System I/O module is a dual-wide VME-based slave
board used in the Model 493.02 chassis.
Provides box-in and box-out, analog and digital I/O, E-Stop, and
HSM and HPU control.
Contains three general purpose digital input channels and three
general purpose digital output channels.
Interfaces the controller with a hydraulic power unit.
Interfaces the controller with a hydraulic service manifold and
other devices.
Provides one BNC channel for analog output signals. The output
signals are within ±10 V DC.
Provides one BNC channel of analog input. The input signals must
be within ±10 V DC.
J25 Hydraulic Power Unit Connection
Connector J25 HPU controls the hydraulic power unit (HPU).
The connector provides 24 V logic signals to control the HPU.
The connector may be connected directly to MTS Series 505 HPUs,
other MTS HPUs via the Model 493.07 HPU Converter Box, and
24 V PLC compliant HPUs.
Note See “Hydraulic Configurations” on page 221 for more information.