RAW WATER CIRCUIT (open circuit)
Number of cylinders
16
Raw water pump: Inlet pressure, min. L bar -0.4
Raw water pump: Inlet pressure, max. L bar +0.5
Pressure loss in off-engine raw water system, max. L bar 0.7
LUBE OIL SYSTEM
Number of cylinders
16
Lube-oil operating temperature before engine, from R °C 78
Lube oil operating temperature before engine, to R °C 86
Lube oil operating pressure upstream of engine, from R bar 6.5
Lube-oil operating pressure before engine, to R bar 7.5
Lube oil operating pressure (low idle) (meas. point: before engine) R bar 2.5
FUEL SYSTEM
Number of cylinders
16
Fuel pressure at engine inlet connection, min. (when engine is starting) L bar -0.3
Fuel pressure at supply connection to engine, min. (when engine is running), L bar -0.3
Fuel pressure at engine inlet connection, max. (when engine is starting) L bar +0.25
Fuel supply flow, max. R Liter/min 8.0
GENERAL OPERATING DATA
Number of cylinders
16
Firing speed, from R rpm 100
Firing speed. to R rpm 120
STARTER (electric)
Number of cylinders
16
Rated starter voltage (standard design) R V= 24
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders
16
Longitudinal inclination, continuous max. driving end down (option: max. oper-
ating inclinations)
L degrees 15
Longitudinal inclination, temporary max. driving end down (option: max. oper-
ating inclinations)
L degrees 22.5
Longitudinal inclination, continuous max. driving end up (option: max. operat-
ing inclinations)
L degrees 0
Longitudinal inclination, temporary max. driving end up (option: max. operating
inclinations)
L degrees 10
Transverse inclination continuous max. (option: max. operating inclinations) L degrees 22.5
Transverse inclination, temporary max. (option: max. operating inclinations) L degrees 32.5
M015655/05E 2015-06 | Technical Data | 49
TIM-ID: 0000003105 - 002