4.9 Engine – Shutdown
Preconditions
Engine is running in Local mode
NOTICE
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
Before shutting down, disengage gear and run the engine at idle speed for at least 10 minutes
until engine temperatures have dropped and constant values are displayed.
The engine can be stopped from the following points
Item Action
Control stand (→ Operating instructions for electronic system)
Local Operating Panel LOP (→ Operating instructions for electronic system)
Local Operation Station LOS (→ Operating instructions for electronic system)
CCU (→ Operating instructions for electronic system)
62 | Operation | M015655/05E 2015-06
TIM-ID: 0000002298 - 003