7.7 Fuel System
7.7.1 Fuel system – Venting
Preconditions
Engine is stopped and starting disabled.
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Wear protective clothing, protective gloves, and safety glasses / facial protection.
Venting fuel system
1. Unscrew handle (3) at fuel priming pump (2).
2. Open vent plug (1).
3. Operate the pump with the handle (3) until
bubble-free fuel emerges from the vent
plug (1).
4. Close vent plug (1).
5. Unscrew handle (3) at fuel priming
pump (2).
M015655/05E 2015-06 | Task Description | 95