8.13.4 Engine oil – Sample extraction and analysis
Preconditions
MTU Fluids and Lubricants Specifications (A001061/..) are available.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
MTU test kit
5605892099/00 1
DANGER
Components are moving or rotating.
Risk of crushing, danger of parts of the body being caught or pulled in!
Operate the engine at low load only. Keep clear of the danger zone of the engine.
WARNING
Oil is hot.
Oil can contain residue/substances which are harmful to health.
Risk of injury and poisoning!
Allow the product to cool to below 50 °C before beginning work.
Wear protective clothing, protective gloves and goggles/safety mask.
Avoid contact with skin.
Do not inhale oil vapor.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
Wear ear protectors.
Engine oil – Sample extraction
and analysis
1. With the engine running at operating temper-
ature, open screw on flange of centrifugal oil
filter by 1 to 2 rotations.
2. Drain approx. 2 liters engine oil to flush out
the oil sludge.
3. Drain approx. 1 liter engine oil into a clean
container.
4. Close screw (arrowed).
5. Using the equipment and chemicals in the
MTU test kit, analyze the engine oil for:
Dispersancy (spot test)
Proportion of water
Fuel dilution
112 | Lube Oil System, Lube Oil Circuit | MS150049/04E 2017-04