EasyManua.ls Logo

multivac C100 - Select and set process

multivac C100
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
Working with recipes
13.05.2014 43
Saving via keys <1> to
<6>
¾ Press and hold down desired key <1> to <6>.
The message "Recipe saved" appears.
The current values are stored in the selected recipe.
Saving via the “save
recipe” menu
¾ Call up "Recipe, saving" menu.
¾ Using the <arrow> keys, select the desired memory location.
¾ Press the <Function selection> key.
The current values are stored in the selected recipe.
4.8.4 Delete recipe
Info
If the currently loaded recipe is deleted, a new recipe must be
loaded.
¾ Call up "Recipe, deleting" menu.
¾ Select the recipe to be deleted with the <arrow> keys.
¾ Press the <Function selection> key.
The message “completed” appears.
The recipe has been deleted.
4.9 Select and set process
4.9.1 Set standard process
¾ Press <Evacuation> key briefly and enter value for Evacuation
pressure.
¾ For automatic evacuation, decrease the value until Automatic
appears.
The machine controls the evacuation process automatically.
¾ Press <Evacuation> key briefly again and set value for Post-
evacuation time.
¾ Call up the "evacuation" menu.
¾ Set Distribution time.
¾ Set Automatic.
¾ Select Standard process.

Table of Contents