Maintenance
Maintenance recommendation
60 13.05.2014
¾ Check the viewing window in the chamber lid for damage (e.g
scratches, cracks).
¾ If the viewing window in the chamber lid is damaged have it re-
placed immediately by the manufacturer.
¾ Check chamber lid gasket for damage.
¾ Have the chamber lid gasket replaced by the service depart-
ment if necessary.
¾ Check sealing bar for damage.
¾ If necessary, replace the sealing bar, see Section 7.3 "RE-
PLACE THE SEALING BAR".
¾ Check the counter-pressure bar for damage.
¾ If necessary, repair the counter-pressure bar, see Section 7.4
"REPAIR COUNTER-PRESSURE BAR".
7.2.5 Entire machine - Alkaline cleaning and disinfection
¾ See company cleaning guidelines and see Section 6 "CLEANING".
7.2.6 Vacuum pump - Checking oil level, topping up
¾ Check the oil level on the oil sight glass.
¾ If water is present in the oil, change the oil in the vacuum
pump, see Section 7.5 "CHANGE THE OIL IN THE VACUUM PUMP".
¾ If necessary, refill oil,.
7.2.7 Entire machine - Acidic cleaning and disinfection
¾ See company cleaning guidelines and see Section 6 "CLEANING".
7.2.8 Connections - Visual inspection
¾ Disconnect the machine from the mains electricity.
¾ Check power cable for damage.
¾ If present, check that the supply line for inert gas is fitted tightly
and undamaged.
7.2.9 Vacuum system - Check
¾ Perform a vacuum test, see Section 7.8 "PERFORMING THE VAC-
UUM TEST".