© Munters AB, 2020 121
CAUTION
The unit must be grounded at all times!
12.2
Trio Expansion Panel Mount Installation
The Trio Expansion Panel Mount (940-10-10001/8 TRIO EXP PAN-MUR-NO10) consists of
two elements, connected by flat ribbons and internet cable:
•
Front panel (CPU panel)
•
Rear panel Expansion Relay / card panel
•
Precautions
•
Panels
•
Panel Dimensions
•
Panel to Panel Expansion Wiring
12.2.1 P
RECAUTIONS
Ensure the following:
• The setup meets electrical, mechanical and fire enclosure requirements.
• Clearance and creepage distances are maintained.
• Grounding meets industry standards.
• Ambient temperatures do not go above product requirements (50⁰ C).
• Ensure that no contactors are in that closet. Placing this unit in proximity to
contactors results in severe signal interference.