© Munters AB, 2020 56
7.5.2 D
EFINING THE
V
ARIABLE
H
EATERS
•
Define:
o
Min./Max Voltage: Define the voltage in the analogue output port that
corresponds to the 0% and 100% output, respectively. For example, if the
minimum voltage is set to 2V and the maximum to 8V the controller applies
the calculated 0-100% output over a 2V-8V signal.
o
Zone Heater:
Disable (default): Central Heaters, the heater output is related to the
target temperature, these heaters operate according to the average
temperature (no temperature sensors can be assigned to it).
Enable: Zone Heater, the heater output has its own target set-point
and its own sensors assign to it. Zone heater enables the assignment of
temperature sensor/s in temperature definition.
o
KWh: This field displays the amount of kilowatts used. Read-only.