EasyManua.ls Logo

MUTHIANI SECURITY SYSTEMS VT1000 - Vehicle Control and Status Commands

MUTHIANI SECURITY SYSTEMS VT1000
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual of VT1000
- 22 -
8.2 Set receiving physical address name via SMS
Description: To know specific address of device, send an SMS and you receive an SMS with its
location physical address name.
Command: W000000,111
Example: SMS send: W000000,111
Then you will receive an SMS as below picture:
(Note: This function need support of the
GPRS01 or SMS01 tracking platform, address
SMS will be received in text format.)
8.3 Get Google Map’s Link via SMS
Description: You will get a Google map URL after sent the command, click the URL, then the
location can be shown directly on Google maps on your mobile phone.
Command: W000000,100
For example: Send SMS: W000000,100
Then you will get the SMS as below picture:
Note: By click the link, you can get the location
in Google map from your mobile phone.
8.4 To cut off Engine, immobilize the vehicle
Command: W000000,020,P,F
Description: P=1, means output1; P=2, means output2 ... P=5, means output5
F=0, to disable this output function; F=1, to enable this output function
SMS send: W000000,020,1,1
If the output1 is connect to oil-cut relay, this command is to enable the engine-cut function, the
engine oil pump line will be cut-off to immobilize the vehicle.
While send W000000,020,1,0 is to restore the engine oil pump line and the vehicle can be started
again.
8.5 Set over speed alarm
Command: W000000,005,XX
Description: XX(the speed preset value) XX=00, disable XX=[01<XX<20](unit:10Km)
Example:
SMS send: W000000,005,10
SMS receive: SET OK! SPEED LIMIT:100Km/h
Meaning: If your speed is over 100Km/h, an alarm SMS will send to your phone to warn you.
8.6 Oil leaking/Refuel Alarm
SMS command: W000000,094,X
Description: X = 000~199(unit: second), means for fuel capacity change exceed preset value in
the time interval X, it will send out oil leaking or fueling alarm, send alarm data to tracking
platform, the leaking protocol number is 0x74, the fueling protocol number is 0x76. And if X is
less than or equal to 5 seconds, then the function will be disabled. System default value is 10