User Manual of VT1000
- 30 -
10km/h and GPS is
available.
=0, to disable the output
=1, to enable the output
=2, to remain previous status
Set power saving mode
when VT1000 is still
(In power saving mode, GPS
stops working. GSM enters
standby mode and stop
sending out message until it is
activated by an SMS or an
incoming call)
W******,026,XX XX=00, to disable this
function
XX=01~99, to set this
function. It is in
unit of minute.
Example:
If XX=10, VT1000 will enter
power
saving mode in 10 minutes
after it is
immobile.
Set phone number for
wiretapping
W******,030,T T is the telephone number for
wiretapping and max. 16 digits
Set time zone difference W******,032,T T=0, to disable this function
T=[1, 65535] to set time
difference in
minutes to GMT.
Default value is GMT
+, not necessary for those
ahead of
GMT. For example, either
+120 or 120
is acceptable.
-, required for those behind
GMT. For
example, -120.
Set character for SOS alert
message
W******,033,P,Char Char P is the button number.
P=1, 2, or 3.
Char is the character in SOS
message
and max 32 characters
Set tracking by driving angle
change function
W******,036,Degree
Measured by Degree(s),
Degree=0,disable this
functionX=1-359means set
angle degree interval in this
function.
Set tracking by distance
function
W******,045,X Measured by Meter(s),
X=0, disable this function
X=1—65535 means the
distance interval in this
function.