42 RadMan 2LT/2XT
13 RadMan 2LT quick reference guide
Display of the maximum exposure that has occurred since the last time the device
was switched on:
Press 1x.
Display returns to the Monitor operating mode after 5 s.
Display of the battery capacity
:
Monitor operating mode
Switch on the device
Press > 1 s.
Switch off the device
Press > 2 s.
Applications The monitor is worn on the body and warns of electromagnetic
radiation.
Integration time 1s
Frequency range Up to 8 GHz
Field exposure
display
5 200%, illuminated individual red LED indicates
measurement value for E- or H-field (whichever is higher)
Alarm threshold 1
50% exposure
and higher
Alarm LED flashes slowly
Alarm signal sounds slowly
Slow vibration
Alarm threshold 2
100% exposure
and higher
Alarm LED flashes rapidly
Alarm signal sounds rapidly
Fast vibration
Power supply/charge mode via USB
Batteries are fully charged (800 h operating time with one battery charge)
Remaining operating time in battery mode < 5%