NI myDAQ
NI myDAQ is a low-cost portable data acquisition (DAQ) device that uses NI LabVIEW-based
software instruments, allowing students to measure and analyze real-world signals. NI myDAQ
is ideal for exploring electronics and taking sensor measurements. Combined with NI LabVIEW
on the PC, students can analyze and process acquired signals and control simple processes
anytime, anywhere.
Figure 1. NI myDAQ
Contents
Safety Information.................................................................................................................... 2
Electromagnetic Compatibility Guidelines .............................................................................. 3
NI myDAQ Hardware Overview.............................................................................................. 3
Analog Input (AI) ............................................................................................................. 4
Analog Output (AO) ......................................................................................................... 4
Digital Input/Output (DIO)............................................................................................... 5
Power Supplies ................................................................................................................. 5
Digital Multimeter (DMM) .............................................................................................. 5
NI myDAQ Software Overview ............................................................................................... 6
NI ELVISmx Driver Software.......................................................................................... 6
NI LabVIEW and NI ELVISmx Express VIs .................................................................. 6
NI myDAQ and NI Multisim............................................................................................ 6
Getting Started .......................................................................................................................... 6
ni.com/manuals
DeutschFrançais
NI myDAQ
AUD
I
O
IN
Analog
In
put
US
B
P
ower Supply
G
a
in
A
n
alog
Output
Digital I
n
put/Output
AU
D
I
O
O
U
T
NI
myDA
Q
S
y
st
em
D
iagr
am
AI
DI
O
5
V
±
15 V
D
C-to
DC
Co
n
ve
r
ter
Analog-
to-Digital
Co
nverte
r
D
ig
it
a
l-
to
-
A
n
a
lo
g
Co
n
v
e
r
te
r
D
ig
ita
l
M
u
ltimet
e
r
A
n
a
l
o
g
I
C
s
s
u
p
p
li
e
d
b
y
H
I
H
I
1
A
1
A
MA
X
MA
X
60
V
20 V
r
ms
2
0
V
r
ms
M
AX
MA
X
A
C
O
M
V
Ω
A
S
ystem
T
imin
g
Con
t
roller
Cu
rr
e
nt
L
imit
e
r
AO
Sw
it
c
h
M
ul
t
i
pl
e
x
e
r
Question and Answer IconNeed help?

Do you have a question about the National Instruments myDAQ and is the answer not in the manual?

National Instruments myDAQ Specifications

General IconGeneral
BrandNational Instruments
ModelmyDAQ
CategoryIndustrial Equipment
LanguageEnglish

Summary

Safety Information

Electromagnetic Compatibility Guidelines

NI myDAQ Hardware Overview

Analog Input (AI)

Details on the two analog input channels, their configuration, and measurement capabilities.

Analog Output (AO)

Details on the two analog output channels, their configuration, and signal generation.

Digital InputOutput (DIO)

Description of the eight software-timed digital I/O lines and their counter/timer functionality.

Power Supplies

Details on the three available power supplies and their total power budget.

Digital Multimeter (DMM)

Overview of the NI myDAQ's Digital Multimeter capabilities for measurements.

NI myDAQ Software Overview

NI ELVISmx Driver Software

The driver software that enables NI ELVISmx instruments to control the NI myDAQ device.

NI LabVIEW and NI ELVISmx Express VIs

LabVIEW Express VIs for interactive configuration of NI myDAQ instruments.

NI myDAQ and NI Multisim

Using NI ELVISmx instruments in NI Multisim for circuit simulation and measurement.

Getting Started

Making Signal Connections with NI myDAQ

Setting up Your NI myDAQ Device

Step-by-step guide to correctly connecting and setting up the NI myDAQ device.

Connecting Signals

Connecting Analog Input Signals

Ground-Referenced Signal Sources

Explanation of signal sources connected to the building system ground for measurement.

Floating Signal Sources

Guidance for connecting floating signal sources to NI myDAQ for accurate measurements.

NI myDAQ DMM Fuse Replacement

Testing Your Fuse

Procedure to test if the NI myDAQ DMM fuse has blown.

Replacing the Fuse

Steps for safely replacing a blown fuse in the NI myDAQ device.

Digital IO (DIO) and CountersTimers

Using NI myDAQ with NI ELVISmx Software Instruments

NI ELVISmx Instrument Launcher

Accessing and launching the suite of NI ELVISmx software instruments.

Digital Multimeter (DMM)

Oscilloscope (Scope)

Function Generator (FGEN)

Bode Analyzer

Dynamic Signal Analyzer (DSA)

Arbitrary Waveform Generator (ARB)

Digital Reader

Digital Writer

Example: Measuring a Signal Using the NI ELVISmx Oscilloscope with NI myDAQ

Using NI myDAQ with LabVIEW

NI ELVISmx Express VIs in LabVIEW

Overview of NI ELVISmx Express VIs for interactive LabVIEW programming of NI myDAQ.

Example: Measuring Signals Using the NI ELVISmx Oscilloscope Express VI with NI myDAQ

Using NI-DAQmx with NI myDAQ

Example: Measuring Audio Pass-Through in LabVIEW with NI myDAQ

Texas Instruments Components in NI myDAQ

Resource Conflicts

Additional Resources

Related Documentation

List of related documents for further information on NI myDAQ, ELVISmx, LabVIEW, and Multisim.

Other Resources

Links to online resources for product information, support, and learning modules.

Common Terms and Acronyms

Warranty

Worldwide Support and Services