Chapter 6: Maintenance 6-3
MSR Cleaning Procedures
MSR Cleaning Cards and MSR Treatment Cards may be purchased from NCR or KIC
Products. For details, see http://www.ncr-direct.com
or http://www.kicproducts.com.
MSR Cleaning and Treatment Cards
Part Part Number NCR Part Number
MSR Cleaning Card, Dry 998-0052929
MSR Cleaning Card, Wet 520522 (box of 50) 603-9014730
MSR Treatment Card 9436-2446 (box of 20) 497-0453056
MSR Treatment Card
The MSR Treatment Card is used to assist in protecting Magnetic Stripe Readers from
Electrostatic Discharge (ESD), which can cause failures when swiping cards that have metallic
hologram stripes.
Swipe the card through the MSR in a smooth motion. Only swipe it down ONCE and up
ONCE. Allow the device to dry for 5 minutes before swiping any other cards.
Note: Each long side of the card may be used twice. Each short side of the card may be used
only once. Thus, a single card can treat 6 MSR devices with one UP and one DOWN swipe per
MSR device. These limits should not be exceeded due to the possibility of spreading
contaminants from machine to machine and/or reducing ESD protection.
Note: If all six up/down swipes are not used on a fresh card it should be placed in a sealed
(Ziploc) bag for future use.

Table of Contents