Touch Screen Calibration 3-11
Verifying the Calibration
1. SelecttheToolstab.
2. SelecttheDrawingTestbutton.
3. Testthecalibrationonthedrawscreen.
Touchthescreeninvariousspotsandtraceeachofthehorizontalandvertical
lines,includingtheborderaroundthescreen.
Inthistest,alltouchesarepersistent,includingtouchdowns(greendots)and
touchups(reddots).
Aftertracingthelines,reviewthedrawnlinestomakesuretheycloselyfollowthe
underlyingpattern.Paycloseattentiontotheedgesofthedisplayandthecorners
sincethisiswhereanincorrectcalibrationismostnoticeable.Ifalineorpoint
appearstobeoutsidethepattern,trypressingtheareatoseehowfarthecursoris
fromthetouchpoint.Iftheregisteredtouchisgreaterthan7mmawayfromwhere
thetouchoccurred,repeatthecalibration.
4. SelectExittoclosethisscreenandtoreturntotheMicrochipTSHARCControl
Panel.
5. Selectthe
CalibrationtabtorepeatthecalibrationprocedureorselectApplyand
thenOKifyouaresatisfiedwiththeresultsandwanttoclosetheapplication.