NCR SelfServ 28 ATM Site Preparation
22 B006-6884-A000
REQUIREMENTS FOR THE FLOOR
The ATM is suitable for mounting on a concrete or other non-combustible surface only.
The surface on which the ATM is to be sited should be level and even.
Floor Loading
The ATM must be installed on a floor capable of supporting the maximum weight. Only
the maximum weight should be considered as additional options may be added after
installation.
CEN I & CEN L
Maximum weight
550 kg
(1213 lb.)
Floor loading
1813 kg/m²
(372 lb./ft²)