Section 5: Data and SMDR
Aspila EX Hardware Manual Section 5: Data and SMDR 5-3
5
Ports for APR Adapter
The APR Adapter’s extension number is determined when the adapter is connected to the system
phone. After assigning the APR Adapter a circuit type of ‘12’ in Program 10-03-06, the system auto-
matically selects the next available port within the APR’s range (193-256). The system assigns the
ports numbers from highest to lowest (256, 255, 254, etc.). Program 10-03-07 indicates which port is
assigned for the APR Adapter. You can reassign the extension number for the port using Program 11-
02-01.
Use the table below to determine the extension number associated with the port number.
Programming for System and Alarm Reports
• 90-13-01 : System Information Output - Output Port Type
Indicate the type of connection used for the SMDR (0=No setting, 1=COM port (NTCPU),
2=USB port (NTCPU), 4= CTA/CTU).
• 90-13-02 : System Information Output - Destination Extension Number
If the output port type (item 1) is set to CTA, enter the extension number with the CTA connec-
tion.
• 90-13-03 : System Information Output - Output Command
Dialing 1 from this program sends the system report to the connected device.
• 90-12-01 : System Alarm Output - Output Port Type
Indicate the type of connection used for the System Alarms. The baud rate for the COM port
should be set in Program 10-21-02 (0=No setting, 1=COM port (NTCPU), 2=USB port
(NTCPU), 4=CTA/CTU).
• 90-12-02 : System Alarm Output - Destination Extension Number
If the output port type (item 1) is set to CTA, enter the extension number with the CTA connec-
tion.
• 90-12-06 : System Alarm Output - Output Mode
Indicate if the output for the alarms should be manual (0) or automatic (1).
Use the following programs for outputting or clearing the alarm reports:
• 90-12-03 : System Alarm Output - Output All Alarm Reports
• 90-12-04 : System Alarm Output - Printout New Alarm Reports
• 90-12-06 : System Alarm Output - Clear All Alarm Reports
Refer to Data Communications Interface in the Software Manual for additional details.
APR Extension Port Number Extension Number
193 493
: :
199 499
200 5000
::
256 5056