Section 2: PCB Installation and Startup
Aspila EX Hardware Manual Section 2: PCB Installation and Startup 2-55
2
Identifying Port Location
Port information such as PCB type, port numbers, PCB status, and individual port status can be
obtained from the system. To obtain a System Report containing PCB information, the system must be
connected to a PC or terminal using the serial, USB, or LAN port connector on the NTCPU.
Running program 90-13-03 in MAINTENANCE PROGRAMS prints a system PCB report. Refer to
Program 90-13-03 : System Information Output in the Software Manual. The following is a typical
report:
<<SYSTEM INFORMATION>> 01/03/03 09:49
slot location type assign port condition note
1 1-1 ESIU 1- 16 Running ****---- -------- Con-
nect:*
2 1-2 ESIU 1- 8 Running
3 1-3 SLIU 1- 8 Running
4 1-4 COIU 1- 16 Running
5 1-5 COIU 1- 16 Running
6 1-6 DIOPU 1- 8 Not Install
7 1-7 - none -
8 1-8 - none -
9 2-1 - none -
10 2-2 - none -
11 2-3 - none -
12 2-4 - none -
13 2-5 - none -
14 2-6 - none -
15 2-7 - none -
16 2-8 - none -