EasyManua.ls Logo

NEC ASPILA EX - Tie Line (4 TLIU) PCB (Figure 2-14)2

NEC ASPILA EX
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 2: PCB Installation and Startup
2-28 Section 2: PCB Installation and Startup Aspila EX Hardware Man-
Tie Line (4TLIU) PCB (Figure 2-14)
The 4TLIU Tie Line PCB is an out band dial type analogue tie line interface PCB. The PCB supports
system connections to either 2-wire (four lead, tip/ring) or 4-wire (eight lead, tip/ring/tip 1/ring 1)
E&M signalling tie lines (determined in Program 10-03). Using switches on the PCB, each circuit type
can be set as Type I, II, III, IV, or V. Each PCB provides:
4 4-circuit tie line interfaces
4 tie line status LEDs
1 PCB status LED
1 run/block switch
2 straps and 1 switch per circuit to determine the circuit type
A maximum of 16 PCBs per system are allowed, providing 64 tie line trunks and it can be plugged into
any universal slot.
The PCB contains 2 straps and 1 switch. How these items are set determines the type of signaling the
system uses. The type of lines the central office provides the customer determines how these switches
should be set.
! Important !
When a router or multiplexer is connected instead of a trunk, the SG terminal of the router or mul-
tiplexer must be connected to the PBXG and FG grounding terminals on the Aspila EX cabinet.
When a trunk is connected, the PBXG and FG terminals must be connected to Earth. If the PBXG
terminal is not connected correctly, the signal may fail.
Circuit Type
Channel/Circuit Number 1-4
(CN100-CN400)
SWn01
Setting
1
Sn01
Setting
1
Sn02
Setting
1
I I Short Short
II I Open Open
III V Open Short
IV I Open Open
V V Short Short
1
The “n” is the circuit number (1-4) being set.