Problem Solving 5-15
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description Action
B
BMC Unsync - - PCI module #1 The BMC cannot be synchronized.
BMC1 broken Green Blink PCI module #1 BMC failure
BMC2 broken Green Blink PCI module #2 BMC failure
Contact your service
representative.
C
CPU IERR 11 Green Blink CPU module #1 CPU#1 internal error
CPU IERR 12 Green Blink CPU module #1 CPU#2 internal error
CPU IERR 21 Green Blink CPU module #2 CPU#1 internal error
CPU IERR 22 Green Blink CPU module #2 CPU#2 internal error
CPU T-Trip 11 Green Blink CPU module #1 CPU#1 thermal change error
(upper limit)
CPU T-Trip 12 Green Blink CPU module #1 CPU#2 thermal change error
(upper limit)
CPU T-Trip 21 Green Blink CPU module #2
CPU#1 thermal change error
(upper limit)
CPU T-Trip 22 Green Blink CPU module #2 CPU#2 thermal change error
(upper limit)
Contact your service
representative.
CPU1 +12v Alm 00 Amber Blink CPU module #1 12-V power voltage alarm (lower
limit)
CPU1 +12v Alm 02 Amber Lit CPU module #1 Fatal 12-V power voltage alarm
(lower limit)
CPU1 +12v Alm 07 Amber Blink CPU module #1 12-V power voltage alarm (upper
limit)
CPU1 +12v Alm 09 Amber Lit CPU module #1
Fatal 12-V power voltage alarm
(upper limit)
CPU1 +2.5vAlm 00 Amber Blink CPU module #1 2.5-V power voltage alarm (lower
limit)
CPU1 +2.5vAlm 02 Amber Lit CPU module #1 Fatal 2.5-V power voltage alarm
(lower limit)
CPU1 +2.5vAlm 07 Amber Blink CPU module #1 2.5-V power voltage alarm (upper
limit)
CPU1 +2.5vAlm 09 Amber Lit CPU module #1 Fatal 2.5-V power voltage alarm
(upper limit)
CPU1 +3.3vAlm 00 Amber Blink CPU module #1
3.3-V power voltage alarm (lower
limit)
CPU1 +3.3vAlm 02 Amber Lit CPU module #1 Fatal 3.3-V power voltage alarm
(lower limit)
CPU1 +3.3vAlm 07 Amber Blink CPU module #1 3.3-V power voltage alarm (upper
limit)
CPU1 +3.3vAlm 09 Amber Lit CPU module #1 Fatal 3.3-V power voltage alarm
(upper limit)
CPU1 +5.0vAlm 00 Amber Blink CPU module #1 5-V power voltage alarm (lower limit)
CPU1 +5.0vAlm 02 Amber Lit CPU module #1 Fatal 5-V power voltage alarm (lower
limit)
CPU1 +5.0vAlm 07 Amber Blink CPU module #1 5-V power voltage alarm (upper
limit)
CPU1 +5.0vAlm 09 Amber Lit CPU module #1 Fatal 5-V power voltage alarm
(upper limit)
Contact your service
representative.