5-16 Problem Solving
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description Action
CPU1 +5.0vsAlm00 Amber Blink CPU module #1 5-V power voltage alarm (lower limit)
CPU1 +5.0vsAlm02 Amber Lit CPU module #1 Fatal 5-V power voltage alarm (lower
limit)
CPU1 +5.0vsAlm07 Amber Blink CPU module #1 5-V power voltage alarm (upper
limit)
CPU1 +5.0vsAlm09 Amber Lit CPU module #1 Fatal 5-V power voltage alarm
(upper limit)
CPU1 Broken Green Blink CPU module #1 CPU module failure
Contact your service
representative.
CPU1 FAN Alm 01 Amber Blink CPU module #1 Cooling fan 1 alarm
CPU1 FAN Alm 02 Amber Blink CPU module #1 Cooling fan 2 alarm
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU FANvltAlm00 Amber Blink CPU module #1 Voltage alarm (lower limit) of the
CPU module cooling fan
CPU FANvltAlm02 Amber Lit CPU module #1 Fatal voltage alarm (lower limit) of
the CPU module cooling fan
CPU FANvltAlm07 Amber Blink CPU module #1 Voltage alarm (upper limit) of the
CPU module cooling fan
CPU FANvltAlm09 Amber Lit CPU module #1 Fatal voltage alarm (upper limit) of
the CPU module cooling fan
CPU1 Missing Green Blink CPU module #1 CPU not found
Contact your service
representative.
CPU1 offline Green Blink CPU module #1 The CPU module has been logically
disconnected.
Activate the ft server utility, or
remove the module and then
mount it again. If the same
error message is still
displayed, contact your
service representative.
CPU1 removed Green Blink CPU module #1 The CPU module has come off. Check the module for a
removed screw, or remove the
module and then mount it
again. If the same error
message is still displayed,
contact your service
representative.
CPU1 Temp Alm 00 Amber Blink CPU module #1 Temperature alarm (lower limit)
CPU1 Temp Alm 02 Amber Lit CPU module #1 Fatal temperature alarm (lower limit)
CPU1 Temp Alm 07 Amber Blink CPU module #1 Temperature alarm (upper limit)
CPU1 Temp Alm 09 Amber Lit CPU module #1 Fatal temperature alarm (upper limit)
CPU11 TempAlm 00 Amber Blink CPU module #1 CPU#1 temperature alarm (lower
limit)
CPU11 TempAlm 02 Amber Lit CPU module #1 Fatal CPU#1 temperature alarm
(lower limit)
CPU11 TempAlm 07 Amber Blink CPU module #1 CPU#1 temperature alarm (upper
limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.