EasyManua.ls Logo

NEC Express5800 320La - Page 171

NEC Express5800 320La
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Problem Solving 5-17
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description Action
CPU11 TempAlm 09 Amber Lit CPU module #1 Fatal CPU#1 temperature alarm
(upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU11 VoltAlm 00 Amber Blink CPU module #1 CPU#1 operating voltage alarm
(lower limit) (VCCP)
CPU11 VoltAlm 02 Amber Lit CPU module #1 Fatal CPU#1 operating voltage
alarm (lower limit) (VCCP)
CPU11 VoltAlm 07 Amber Blink CPU module #1 CPU#1 operating voltage alarm
(upper limit) (VCCP)
CPU11 VoltAlm 09 Amber Lit CPU module #1 Fatal CPU#1 operating voltage
alarm (upper limit) (VCCP)
Contact your service
representative.
CPU12 TempAlm 00 Amber Blink CPU module #1 CPU#2 operating voltage alarm
(lower limit)
CPU12 TempAlm 02 Amber Lit CPU module #1 Fatal CPU#2 temperature alarm
(lower limit)
CPU12 TempAlm 07 Amber Blink CPU module #1 CPU#2 temperature alarm (upper
limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU12 TempAlm 09 Amber Lit CPU module #1 Fatal CPU#2 temperature alarm
(upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU12 VoltAlm 00 Amber Blink CPU module #1 CPU#2 operating voltage alarm
(lower limit) (VCCP)
CPU12 VoltAlm 02 Amber Lit CPU module #1 Fatal CPU#2 operating voltage
alarm (lower limit) (VCCP)
CPU12 VoltAlm 07 Amber Blink CPU module #1 CPU#2 operating voltage alarm
(upper limit) (VCCP)
CPU12 VoltAlm 09 Amber Lit CPU module #1 Fatal CPU#2 operating voltage
alarm (upper limit) (VCCP)
Contact your service
representative.
CPU1 FANvltAlm02 Amber Lit CPU module #1 Fatal voltage alarm (lower limit) of
the CPU module cooling fan
CPU1 FANvltAlm07 Amber Blink CPU module #1 Voltage alarm (upper limit) of the
CPU module cooling fan
CPU1 FANvltAlm09 Amber Lit CPU module #1 Fatal voltage alarm (upper limit) of
the CPU module cooling fan
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU1 Missing Green Blink CPU module #1 CPU not found
CPU1 offline Green Blink CPU module #1 The CPU module has been logically
disconnected.
CPU1 removed Green Blink CPU module #1 The CPU module has come off.
Contact your service
representative.

Table of Contents

Other manuals for NEC Express5800 320La

Related product manuals