5-18 Problem Solving
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description Action
CPU2 Temp Alm 00 Amber Blink CPU module #2 Temperature alarm (lower limit)
CPU2 Temp Alm 02 Amber Lit CPU module #2 Fatal temperature alarm (lower limit)
CPU2 Temp Alm 07 Amber Blink CPU module #2 Temperature alarm (upper limit)
CPU2 Temp Alm 09 Amber Lit CPU module #2 Fatal temperature alarm (upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU2 +12v Alm 00 Amber Blink CPU module #2 12-V power voltage alarm (lower
limit)
CPU2 +12v Alm 02 Amber Lit CPU module #2 Fatal 12-V power voltage alarm
(lower limit)
CPU2 +12v Alm 07 Amber Blink CPU module #2
12-V power voltage alarm (upper
limit)
CPU2 +12v Alm 09 Amber Lit CPU module #2 Fatal 12-V power voltage alarm
(upper limit)
Contact your service
representative.
CPU2 +2.5vAlm 00 Amber Blink CPU module #2 2.5-V power voltage alarm (lower
limit)
CPU2 +2.5vAlm 02 Amber Lit CPU module #2 Fatal 2.5-V power voltage alarm
(lower limit)
CPU2 +2.5vAlm 07 Amber Blink CPU module #2 2.5-V power voltage alarm (upper
limit)
CPU2 +2.5vAlm 09 Amber Lit CPU module #2 Fatal 2.5-V power voltage alarm
(upper limit)
CPU2 +3.3vAlm 00 Amber Blink CPU module #2 3.3-V power voltage alarm (lower
limit)
CPU2 +3.3vAlm 02 Amber Lit CPU module #2 Fatal 3.3-V power voltage alarm
(lower limit)
CPU2 +3.3vAlm 07 Amber Blink CPU module #2 3.3-V power voltage alarm (upper
limit)
CPU2 +3.3vAlm 09 Amber Lit CPU module #2 Fatal 3.3-V power voltage alarm
(upper limit)
CPU2 +5.0vAlm 00 Amber Blink CPU module #2 5-V power voltage alarm (lower limit)
CPU2 +5.0vAlm 02 Amber Lit CPU module #2 Fatal 5-V power voltage alarm (lower
limit)
CPU2 +5.0vAlm 07 Amber Blink CPU module #2 5-V power voltage alarm (upper
limit)
CPU2 +5.0vAlm 09 Amber Lit CPU module #2
Fatal 5-V power voltage alarm
(upper limit)
CPU2 +5.0vsAlm00 Amber Blink CPU module #2 5-V power voltage alarm (lower limit)
CPU2 +5.0vsAlm02 Amber Lit CPU module #2
Fatal 5-V power voltage alarm (lower
limit)
CPU2 +5.0vsAlm07 Amber Blink CPU module #2 5-V power voltage alarm (upper
limit)
CPU2 +5.0vsAlm09 Amber Lit CPU module #2 Fatal 5-V power voltage alarm
(upper limit)
CPU2 broken Green Blink CPU module #2 CPU module failure
Contact your service
representative.
CPU2 FAN Alm 01 Amber Blink CPU module #2 Cooling fan 1 alarm
CPU2 FAN Alm 02 Amber Blink CPU module #2 Cooling fan 2 alarm
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.