5-20 Problem Solving
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description Action
CPU22 TempAlm 00 Amber Blink CPU module #2 CPU#2 temperature alarm (lower
limit)
CPU22 TempAlm 02 Amber Lit CPU module #2 Fatal CPU#2 temperature alarm
(lower limit)
CPU22 TempAlm 07 Amber Blink CPU module #2 CPU#2 temperature alarm (upper
limit)
CPU22 TempAlm 09 Amber Lit CPU module #2 Fatal CPU#2 temperature alarm
(upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU22 VoltAlm 00 Amber Blink CPU module #2 CPU#2 operating voltage alarm
(lower limit) (VCCP)
CPU22 VoltAlm 02 Amber Lit CPU module #2 Fatal CPU#2 operating voltage alarm
(lower limit) (VCCP)
CPU22 VoltAlm 07 Amber Blink CPU module #2 CPU#2 operating voltage alarm
(upper limit) (VCCP)
CPU22 VoltAlm 09 Amber Lit CPU module #2 Fatal CPU#2 operating voltage alarm
(upper limit) (VCCP)
Contact your service
representative.
D
DUMP Request! Off - DUMP switch request Contact your service
representative.
F
FRB Processing Off - During POST execution or OS start
processing
The server is operating
normally.
M
Memory U-Err 11 Green Blink CPU module #1 DIMM#1 2-bit error
Memory U-Err 12 Green Blink CPU module #1 DIMM#2 2-bit error
Memory U-Err 13 Green Blink CPU module #1 DIMM#3 2-bit error
Memory U-Err 14 Green Blink CPU module #1 DIMM#4 2-bit error
Memory U-Err 21 Green Blink CPU module #2 DIMM#1 2-bit error
Memory U-Err 22 Green Blink CPU module #2 DIMM#2 2-bit error
Memory U-Err 23 Green Blink CPU module #2 DIMM#3 2-bit error
Memory U-Err 24 Green Blink CPU module #2 DIMM#4 2-bit error
The DIMM needs to be
replaced. Contact your
service representative.
O
OS shutdown Alm Off - Shutdown due to a timeout error of
the Watch dog timer (fatal error)
Contact your service
representative.
P
PCI1 +12v Alm 00 Amber Blink PCI module #1 12-V power voltage alarm (lower limit)
PCI1 +12v Alm 02 Amber Lit PCI module #1 Fatal 12-V power voltage alarm (lower
limit)
PCI1 +12v Alm 07 Amber Blink PCI module #1 12-V power voltage alarm (upper
limit)
PCI1 +12v Alm 09 Amber Lit PCI module #1 Fatal 12-V power voltage alarm
(upper limit)
Contact your service
representative.