5-22 Problem Solving
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description Action
PCI1 Temp Alm 00 Amber Blink PCI module #1 Temperature alarm (lower limit)
PCI1 Temp Alm 02 Amber Lit PCI module #1 Fatal temperature alarm (lower limit)
PCI1 Temp Alm 07 Amber Blink PCI module #1 Temperature alarm (upper limit)
PCI1 Temp Alm 09 Amber Lit PCI module #1 Fatal temperature alarm (upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
PCI2 +12v Alm 00 Amber Blink PCI module #2 12-V power voltage alarm (lower limit)
PCI2 +12v Alm 02 Amber Lit PCI module #2 Fatal 12-V power voltage alarm (lower
limit)
PCI2 +12v Alm 07 Amber Blink PCI module #2 12-V power voltage alarm (upper
limit)
PCI2 +12v Alm 09 Amber Lit PCI module #2 Fatal 12-V power voltage alarm
(upper limit)
PCI2 +3.3vAlm 00 Amber Blink PCI module #2 3.3-V power voltage alarm (lower
limit)
PCI2 +3.3vAlm 02 Amber Lit PCI module #2 Fatal 3.3-V power voltage alarm
(lower limit)
PCI2 +3.3vAlm 07 Amber Blink PCI module #2 3.3-V power voltage alarm (upper
limit)
PCI2 +3.3vAlm 09 Amber Lit PCI module #2 Fatal 3.3-V power voltage alarm
(upper limit)
PCI2 +3.3vsAlm00 Amber Blink PCI module #2 3.3-V power voltage alarm (lower
limit)
PCI2 +3.3vsAlm02 Amber Lit PCI module #2 Fatal 3.3-V power voltage alarm
(lower limit)
PCI2 +3.3vsAlm07 Amber Blink PCI module #2 3.3-V power voltage alarm (upper
limit)
PCI2 +3.3vsAlm09 Amber Lit PCI module #2 Fatal 3.3-V power voltage alarm
(upper limit)
PCI2 +5.0vAlm 00 Amber Blink PCI module #2 5-V power voltage alarm (lower limit)
PCI2 +5.0vAlm 02 Amber Lit PCI module #2 Fatal 5-V power voltage alarm (lower
limit)
PCI2 +5.0vAlm 07 Amber Blink PCI module #2 5-V power voltage alarm (upper limit)
PCI2 +5.0vAlm 09 Amber Lit PCI module #2 Fatal 5-V power voltage alarm (upper
limit)
Contact your service
representative.
PCI2 Temp Alm 00 Amber Blink PCI module #2 Temperature alarm (lower limit)
PCI2 Temp Alm 02 Amber Lit PCI module #2 Fatal temperature alarm (lower limit)
PCI2 Temp Alm 07 Amber Blink PCI module #2 Temperature alarm (upper limit)
PCI2 Temp Alm 09 Amber Lit PCI module #2 Fatal temperature alarm (upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
Power Major Alm Amber Lit Power unit #1/2 Fatal power (major) alarm Contact your service
representative.
Power On Cnt Alm Amber Lit Power unit #1/2 Fatal power control system failure Check the AC cable. If the
same error message is still
displayed, contact your
service representative.

Table of Contents