3.16 [ 037-3. FILTER USAGE INFORMATION REQUEST ]
Gets filter usage information such as usage time.
Command
03h 95h 00h 00h 00h 98h
Response
When the command succeeds
23h 95h <ID1> <ID2> 08h <DATA01> - <DATA08> <CKS>
Data part
Item Description
DATA01 - 04 Filter usage time (seconds)
DATA05 - 08 Filter alarm start time (seconds)
Information
If no time is defined, "-1" is returned.