98
STEP 20:Press or Exec to start the data backup.
While making a backup copy, the LCD displays
“Uploading...”, and when the data backup suc-
ceeded, LCD displays “Upload Complete!”. If the
data backup failed, LCD displays “Upload Failed!”.
STEP 21:After the data backup is complete, the display
changes as follows:
STEP 22:The display goes back to the Backup/Re-
store screen by Exit.
Exit
Upload Complete!
Note
When the data backup ends in failure, "Upload Failed!"
is displayed on the LCD. Check to see the following and
make a retry.
Check Points Actions
Incorrect IP address of
FTP/TFTP server has
been entered from the
telephone.
Set the proper IP address
of FTP/TFTP server.
The power to FTP/TFTP
server or network
equipment is OFF.
Turn on the power.
LAN cable is
disconnected.
Reconnect the cable
securely.