Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1221
79
Tucker GmbH, Mail / Post: Max-Eyth-Str.1, 35394 Gießen, Germany
F
code
Description
Possible Values
Default
Unit
Notes
F19
Lock Mode
1 to 3
1
x
Mode 1: Use the lock key to toggle blocking on all keys - no
password protec- tion. Mode 2:
Use the lock key to enter a password, lock key as ‘enter’. From
there, all keys are blocked until you press lock again. It will prompt
for the same password entered when originally locked. Pass-
word can be up to 9 characters. Mode 3: Same as mode 2, except
user can tog- gle between presets and cannot change the value of
presets. Mode 4: Same as mode 3 except the user can adjust the
time and current by a percentage as set by F57.
F20
Debug
ENTER DEBUG
MODE
ENTER
DEBUG
MODE
x
Used by manufacturing and service.
F21
User Counter
0 to 4.3B
0
Welds
While in this F code, press and hold the time-down button 3-5
seconds to reset the counter.
F22
Total Counter
0 to 4.3B
0
Welds
(Non-resettable)
F23
Chuck Stripper
OFF ON
OFF
x

Table of Contents